Air Shower Tunnel Tower Flow

The air shower tunnel (tower flow) from Weiber is a protected passageway that allows the user to pass into controlled environment chambers sans the surface contaminants.Our air shower tunnels are designed to provide sterile air streams for the removal of dust and contaminating particles from the clothes and skin surfaces of the user as he/she stands in the tunnel or walks through it.They provide the maximum decontamination solutions for particle sensitive processes and other research applications requiring highly sterile working conditions.
 

Our air showers are easy to operate and are quite economical. They are operational with a simple plug-in to the power source and require minimal maintenance. Our air shower tunnel uses a combination of basic floor plan styles with individual air shower units coupled together side by side or end to end to create a tunnel configuration for the passage of large groups of personnel. They are designed to meet all the industrial specifications, making them perfect for use in pharmaceutical industries, microelectronics and semiconductor industries, aerospace industry, high precision manufacturing units and various other industrial applications.
 

We offer air showers in various sizes and packages in both standard and customized designs to meet the industrial specifications.
 

Working principle

The air circulating within the air shower tunnel passes through the filter assembly, comprising of pre-filters and HEPA filters, for efficient removal of dust and contaminating particles within the equipment. The clean air is then passed through the nozzles at a high velocity to create pressurized air streams, capable of providing enough scrubbing action for the removal of particulate contaminants adhering to the clothes and skin surfaces of the personnel.The contaminated air is then directed downwards through the grilles and hollow walls of the air shower tunnel and is redirected towards the filter assembly for filtration and recirculation.
 

Filter assembly


Our air shower tunnels (tower flow) use top mounted pre-filters and HEPA filters for removing particles as small as 0.3 microns in size and larger with around 99.97% filtration efficiency.The pre-filters are capable of eliminating around 85% of the dust particles, therefore reducing the contaminant load on the HEPA filters and improving its filtration efficiency and life span. The HEPA filters provide a uniform and laminar air flow within the air shower tunnel, therefore ensuring increased air conditioning and energy efficiency while minimizing cross stream contamination.


Construction details


Our air showers useindustrial grade mica clad heavy wooden boards and high grade stainless steel (SS 304 or SS 316) as construction materials. The internal duct surfaces and all the visible surfaces are covered with plastic laminate to provide a uniform surface and are available in attractive finishes. The magnetically operated and interlocked doors on either side of the air shower tunnel do not open at the same time, therefore restricting the leakage of contaminants from the outside in to the clean room and the biohazardous substances from the clean room to the outside. They are made up of aluminium panel and feature clear view glass/acrylic windows to permit visibility. The compartment access panels are made of coated aluminium and are hinged for ease of handling. They are also equipped with appropriate number of adjustable nozzles mounted on the interior walls and ceilings for maintaining high velocity air streams.


Illumination system


Our air showers use top mounted fluorescent lights for adequate illumination of the air shower tunnel. The fluorescent lights are concealed within a light panel and are designed to ensure uniform and even lighting throughout the chamber.The illumination system of our air shower conforms to US federal standards and provides an illumination level of more than 800 lux throughout the air shower tunnel.


Motor and blower assembly


Our air showers use ISI marked, statically and dynamically balanced motors and blower motors with a rating of 1/5 HP. The blower access panel is provided at the side of the shower. The permanently lubricated direct drive centrifugal blowers work in conjugation with the air nozzles to provide continuous high velocity air streams. The high efficiency pumps of our air showers with lifelong lubricated bearings ensure smooth and trouble free operation. The motor and blower assembly has a compact design and is completely integrated for increased energy efficiency and optimum motor cooling. The efficient motors and blowers ensure vibration free and quiet operation.


Programmable operation


The air shower tunnel from Weiber uses microprocessor based controllers for precise control of various operating parameters. The programmable solid statecircuit control system is located at the junction box of the air shower and helps in maintaining optimum conditions of temperature, humidity and illumination within the working chamber. It also facilitates the adjustment and opening and closing of air nozzles and in setting the operation timer from 0-9,990 seconds. The junction box also houses an emergency setting button that allows switching off of the equipment with audio and visual alarms.

 

Key features

·         Ergonomic design for versatile usage

·         Available with calibration protocol documentation and complete self-diagnostic systems.

·         Programmable operation

·         Designed to ensure minimum vibration and noise level < 60 db

·         Lighting arrangement conforms to the guidelines for US federal standards

·         GMP/GLP compliant systems

 

Latest Articles

  • Permanent laser hair removal, best laser hair removal clinic Delhi
    Permanent laser hair removal, best laser hair removal clinic Delhi

    We all want a neat and tidy look on the whole, but unwanted body hair is always a big embarrassmen. Read More

  • Why online education is the cure for raising the bar for education in
    Why online education is the cure for raising the bar for education in

    India boasts of being the youngest nation but it is also among the top five nations with 1.4 million. Read More

  • ITIL Foundation certification gives cutting edge approach towards busi
    ITIL Foundation certification gives cutting edge approach towards busi

    For an organization, the first step towards success is to align the IT services with its business go. Read More

  • Chin Hair Removal Services By Dr. Rohit Batra
    Chin Hair Removal Services By Dr. Rohit Batra

    Chin hair is a common problem for many women and it becomes very embarrassing for them to have hai. Read More

  • All India Entrance Examination for Design - AIEED 2010
    All India Entrance Examination for Design - AIEED 2010

    CEED Exam Schedule 2010 Common Entrance Examination for Design (CEED 2010) [Entrance Exam for MDes . Read More

Latest Classified

Top Featured Institutes